Iintlobo ezili-17 ze-HPV (16/18/6/11/44 Ukuchwetheza)

Inkcazelo emfutshane:

Le khithi ilungele ukufunyaniswa komgangatho weentlobo ezili-17 ze-human papillomavirus (HPV) iintlobo (HPV 6, 11, 16,18,31, 33,35, 39, 44,45, 51, 52.56,58, 59,66, 68) amaqhekeza athile e-nucleic acid kwisampulu yomchamo, isampulu yomfazi womlomo wesibeleko kunye nesampulu ye-swab yelungu lobufazi, kunye ne-HPV 16/18/6/11/44 yokuchwetheza ukunceda ukuxilonga nokunyanga usulelo lwe-HPV.


Iinkcukacha zeMveliso

Iithegi zeMveliso

Igama lemveliso

HWTS-CC015 17 Iindidi ze-Human Papillomavirus (16/18/6/11/44 Ukuchwetheza) IKit ye-Nucleic Acid Detection (Fluorescence PCR)

I-Epidemiology

Umhlaza womlomo wesibeleko lelinye lawona mathumba ayingozi axhaphakileyo kwindlela yokuzala yabasetyhini.Kuye kwaboniswa ukuba usulelo lwe-HPV oluzingisileyo kunye nosulelo oluninzi ngomnye woonobangela abaphambili bomhlaza womlomo wesibeleko.Okwangoku kusekho ukunqongophala konyango olwamkelekileyo jikelele lomhlaza womlomo wesibeleko obangelwa yi-HPV.Ke ngoko, ukufunyaniswa kwangoko kunye nokuthintela usulelo lomlomo wesibeleko olubangelwa yi-HPV zizitshixo zokuthintela umhlaza womlomo wesibeleko.Ukusekwa kweemvavanyo ezilula, ezicacileyo kunye nezikhawulezayo zokuxilonga iintsholongwane zibaluleke kakhulu kuxilongo lwezonyango lomhlaza womlomo wesibeleko.

Umjelo

PCR-Mix1 FAM 18
VIC/HEX

16

ROX

31,33,35,39,45,51,52,56,58,59,66,68

CY5 Ulawulo lwangaphakathi
I-PCR-Mix2 FAM 6
VIC/HEX

11

ROX

44

CY5 Ulawulo lwangaphakathi

IiParameters zobuGcisa

Ugcino

-18℃

Beka ubomi kwishelufa Iinyanga ezili-12
Uhlobo loMfanekiso Isampulu yomchamo, isampulu yeswab yomlomo wesibeleko yabasetyhini, isampulu yeswabhu yelungu lobufazi
Ct ≤28
LoD 300Iikopi/mL
Ukuchaza ngokuthe ngqo Akukho cross-reactivity kunye Ureaplasma urealyticum, Chlamydia trachomatis of reproductive tract, Candida albicans, Neisseria gonorrhoeae, Trichomonas vaginalis, Mold , Gardnerella kunye nezinye iindidi ze-HPV ezingafakwanga kwikiti.
Izixhobo Ezisebenzayo Iinkqubo ze-Biosystems ezisetyenzisiweyo 7500 Iinkqubo zePCR zeXesha langempela
Iinkqubo ze-Biosystems eziSetyenzisiweyo 7500 Iinkqubo zePCR ezikhawulezayo
QuantStudio®IiNkqubo ze-PCR ze-5 zeXesha langempela
SLAN-96P Iinkqubo zePCR zeXesha langempela
I-LightCycler®IiNkqubo ze-PCR ze-480 zeXesha langempela
LineGene 9600 Plus Real-Time PCR Ukufunyanwa Systems
MA-6000 Real-Time Quantitative Thermal Cycler
I-BioRad CFX96 Inkqubo yePCR yexesha lokwenyani
BioRad CFX Opus 96 Real-Time PCR System

Ukuhamba komsebenzi

I-reagent yokutsalwa ecetyiswayo: Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (enokuthi isetyenziswe kunye neMacro & Micro-Test I-Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) yi-Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Yongeza i-200μL ye-saline eqhelekileyo ukumisa kwakhona i-pellet kwinqanaba le-2.1, kwaye ke ukutsalwa kufuneka kuqhutywe ngokuhambelana kwimiyalelo yokusetyenziswa kwesi sixhobo sotsalo.Umthamo we-elution ocetyiswayo yi-80μL.

I-reagent yokutsalwa ecetyiswayo: QIAamp DNA Mini Kit (51304) okanye iMacro & Micro-Test Viral DNA/RNA Column (HWTS-3020-50).Yongeza i-200μL ye-saline eqhelekileyo ukumisa kwakhona i-pellet kwinqanaba le-2.1, kwaye emva koko ukukhutshwa kufuneka kuqhutywe ngokwemiyalelo yokusetyenziswa kwesi sixhobo sokukhupha.Umthamo wesampulu okhutshiweyo weisampulu zonke ziyi-200μL, kwaye umthamo we-elution ocetyiswayo yi-100μL.

I-reagent yokutsalwa ecetyiswayo: I-Macro & Micro-Test yeSample Release Reagent (HWTS-3005-8I, HWTS-3005-8J, HWTS-3005-8K, HWTS-3005-8L).Yongeza i-200μL ye-reagent yokukhululwa kwesampuli ukumisa kwakhona i-pellet kwinqanaba le-2.1, kwaye emva koko ukukhutshwa kufuneka kuqhutywe ngokwemiyalelo yokusetyenziswa kwesi sixhobo sokukhupha.


  • Ngaphambili:
  • Okulandelayo:

  • Bhala umyalezo wakho apha kwaye uwuthumele kuthi