I-Encephalitis B Virus Nucleic Acid

Inkcazo emfutshane:

Le khithi isetyenziselwa ukufumanisa intsholongwane ye-encephalitis B kwi-serum nakwiplasma yezigulane kwi-vitro.


Iinkcukacha zeMveliso

Iithegi zeMveliso

Igama lemveliso

Ikhithi yokuFumanisa iNucleic Acid yeNyukleyitha ye-HWTS-FE003-Encephalitis B Virus (iFluorescence PCR)

I-Epidemiology

I-encephalitis yaseJapan sisifo esosulelayo esithwalwa ngegazi, esiyingozi kakhulu kwimpilo nakubomi bezigulana. Emva kokuba umntu osulelwe yintsholongwane ye-encephalitis B, emva kweentsuku ezi-4 ukuya kwezi-7 zokufunxwa, inani elikhulu leentsholongwane liyasasazeka emzimbeni, kwaye intsholongwane isasazeka kwiiseli esibindini, kwi-spleen, njl. Kwinani elincinci lezigulana (0.1%), intsholongwane emzimbeni inokubangela ukudumba kwe-meninges kunye nezicubu zobuchopho. Ke ngoko, ukuxilongwa ngokukhawuleza kwentsholongwane ye-encephalitis B yeyona nto iphambili kunyango lwe-encephalitis yaseJapan, kwaye ukusekwa kwendlela elula, ecacileyo nekhawulezayo yokuxilonga i-etiological kubaluleke kakhulu ekuxilongweni kwe-encephalitis yaseJapan.

Iiparameters zobugcisa

Indawo yokugcina izinto

-18℃

Beka ubomi kwishelufa Iinyanga ezi-9
Uhlobo lweSibonelelo iisampulu ze-serum, i-plasma
CV ≤5.0%
I-LoD Iikopi ezingama-2000/mL
Izixhobo Ezisebenzayo Isebenza kwi-type I detection reagent:Iinkqubo ze-PCR ze-Applied Biosystems 7500 Real-Time,I-QuantStudio®Iinkqubo ze-PCR ezi-5 zeXesha langempela,

Iinkqubo ze-PCR ze-SLAN-96P zeXesha langempela (iHongshi Medical Technology Co., Ltd.),

Iinkqubo zokuFumanisa i-LineGene 9600 Plus zeXesha langempela ze-PCR (FQD-96A,Itekhnoloji yeHangzhou Bioer),

I-MA-6000 Real-Time Quantitative Thermal Cycler (iSuzhou Molarray Co., Ltd.),

Inkqubo ye-PCR ye-BioRad CFX96 yeXesha langempela,

Inkqubo ye-PCR ye-BioRad CFX Opus 96 yeXesha langempela.

Isebenza kwi-reagent yokuchonga uhlobo lwesibini:

U-EudemonTMI-AIO800 (HWTS-EQ007) yiJiangsu Macro kunye neMicro-Test Med-Tech Co., Ltd.

Ukuhamba komsebenzi

I-Macro & Micro-Test General DNA/RNA Kit (HWTS-3019-50, HWTS-3019-32, HWTS-3019-48, HWTS-3019-96) (engasetyenziswa kunye ne-Macro & Micro-Test Automatic Nucleic Acid Extractor Document No.:HWTS-STP-IFU-JEV Catalog Number: HWTS-FE003A (HWTS-3006C, HWTS-3006B)) yiJiangsu Macro & Micro-Test Med-Tech Co., Ltd. Ukukhupha kufuneka kuqalwe ngokwe-IFU ye-reagent yokukhupha. Umthamo wesampulu okhutshiweyo yi-200μL kwaye umthamo wokucoca ocetyiswayo yi-80 μL.


  • Ngaphambili:
  • Okulandelayo:

  • Bhala umyalezo wakho apha uze uwuthumele kuthi