I-ALDH Genetic Polymorphism

Inkcazo emfutshane:

Le khithi isetyenziselwa ukufumanisa indawo ye-ALDH2 gene G1510A polymorphism kwi-DNA ye-genomic yegazi yomntu.


Iinkcukacha zeMveliso

Iithegi zeMveliso

Igama lemveliso

I-HWTS-GE015Ikhithi yokuFumanisa i-ALDH Genetic Polymorphism (ARMS -PCR)

I-Epidemiology

I-ALDH2 gene (i-acetaldehyde dehydrogenase 2), ifumaneka kwi-chromosome yomntu 12. I-ALDH2 ine-esterase, i-dehydrogenase kunye nomsebenzi we-reductase ngaxeshanye. Izifundo zibonise ukuba i-ALDH2 yi-enzyme ye-metabolic ye-nitroglycerin, eguqula i-nitroglycerin ibe yi-nitric oxide, ngaloo ndlela iphumza imithambo yegazi kwaye iphucule ukuphazamiseka kokuhamba kwegazi. Nangona kunjalo, kukho ii-polymorphisms kwi-ALDH2 gene, ezigxile kakhulu eMpuma Asia. I-ALDH2*1/1 GG yasendle inamandla amakhulu e-metabolic, ngelixa uhlobo lwe-heterozygous lune-6% kuphela yomsebenzi we-enzyme yasendle, kwaye uhlobo lwe-homozygous mutant alunamsebenzi we-enzyme phantse, kunye ne-metabolism ebuthathaka kakhulu kwaye ayinakufezekisa isiphumo esifunekayo, ngaloo ndlela ibangela ingozi emzimbeni womntu.

Itshaneli

I-FAM I-ALDH2
I-ROX

Ulawulo lwangaphakathi

Iiparameters zobugcisa

Indawo yokugcina izinto

≤-18℃

Beka ubomi kwishelufa Iinyanga ezili-12
Uhlobo lweSibonelelo Igazi elichasene nokugaywa kwegazi yi-EDTA
CV <5.0%
I-LoD 103Iikopi/mL
Izixhobo Ezisebenzayo Inkqubo ye-PCR ye-Applied Biosystems 7500 Real-Time

Iinkqubo ze-PCR eziSebenzisiweyo ze-7500 ezikhawulezayo zeXesha langempela

I-QuantStudio®Iinkqubo ezi-5 ze-PCR zeXesha langempela

Iinkqubo ze-PCR ze-SLAN-96P zeXesha langempela

I-LightCycler®Inkqubo ye-PCR yeXesha langempela ye-480

Inkqubo yokuHlola i-PCR yeLineGene 9600 Plus ngexesha langempela

I-MA-6000 Real-Time Quantitative Thermal Cycler

Inkqubo ye-PCR ye-BioRad CFX96 yeXesha langempela

Inkqubo ye-PCR ye-BioRad CFX Opus 96 yeXesha langempela

Ukuhamba komsebenzi

Ii-reagents zokukhupha ezicetyiswayo: sebenzisa i-Blood Genome DNA Extraction Kit (DP318) yiTiangen Biotech (Beijing) Co.,Ltd. okanye i-Blood Genome Extraction Kit (A1120) yiPromega ukuze ukhuphe i-EDTA ye-DNA ye-Genomic blood anticoagulated.

Ii-reagents zokukhupha ezicetyiswayo: I-Macro & Micro-Test General DNA/RNA Kit (HWTS-3019) (engasetyenziswa kunye ne-Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-EQ011)) yiJiangsu Macro & Micro-Test Med-Tech Co., Ltd. Ukukhupha kufuneka kwenziwe ngokwemiyalelo engqongqo. Umthamo wokucoca ocetyiswayo ngu100μL.


  • Ngaphambili:
  • Okulandelayo: