I-Herpes Simplex Virus Uhlobo loku-1
Igama lemveliso
HWTS-UR006 Herpes Simplex Virus Type 1 Nucleic Acid Detection Kit (Fluorescence PCR)
I-Epidemiology
Izifo ezosulela ngokwabelana ngesondo (STDs) zisengomnye wezoyikiso ezibalulekileyo kukhuseleko lwezempilo lukawonke-wonke lwehlabathi, nto leyo enokukhokelela ekubeni ubudlolo, unikezelo ngaphambi kwexesha, amathumba kunye neengxaki ezinzulu ezahlukeneyo.[3-6].Kukho iintlobo ezininzi ze-STD pathogens, kuquka ibhaktheriya, iintsholongwane, i-chlamydia, i-mycoplasma kunye ne-spirochetes.Iindidi eziqhelekileyo ziquka i-neisseria gonorrhoeae, i-mycoplasma genitalium, i-chlamydia trachomatis, i-herpes simplex virus type 1, i-herpes simplex virus type 2, i-mycoplasma hominis, ureaplasma urealyticum, njl.
Umjelo
FAM | I-Herpes Simplex Virus Type 1 (HSV1) |
ROX | Ulawulo lwangaphakathi |
IiParameters zobuGcisa
Ugcino | -18℃ |
Beka ubomi kwishelufa | Iinyanga ezili-12 |
Uhlobo loMfanekiso | Iswabhu yomlomo wesibeleko yabasetyhini,I-swab ye-urethral yamadoda |
Ct | ≤38 |
CV | ≤5.0% |
LoD | 500Iikopi/mL |
Ukuchaza ngokuthe ngqo | Vavanya ezinye iintsholongwane zosulelo lwe-STD, ezifana ne-treponema pallidum, i-chlamydia trachomatis, i-neisseria gonorrhoeae, i-mycoplasma hominis, i-mycoplasma genitalium, i-ureaplasma urealyticum, njl., akukho-cross-reactivity. |
Izixhobo Ezisebenzayo | Iinkqubo ze-Biosystems ezisetyenzisiweyo 7500 Iinkqubo zePCR zeXesha langempela Iinkqubo ze-Biosystems eziSetyenzisiweyo 7500 Iinkqubo zePCR ezikhawulezayo QuantStudio®IiNkqubo ze-PCR ze-5 zeXesha langempela SLAN-96P Iinkqubo zePCR zeXesha langempela I-LightCycler®Inkqubo ye-PCR ye-480 yexesha langempela I-LineGene 9600 Plus Real-Time PCR Detection System MA-6000 Real-Time Quantitative Thermal Cycler I-BioRad CFX96 Inkqubo yePCR yexesha lokwenyani BioRad CFX Opus 96 Real-Time PCR System |
Ukuhamba komsebenzi
Ukhetho loku-1.
I-Macro & Micro-Test Sample Release Reagent (HWTS-3005-8), ukukhutshwa kufuneka kuqhutywe ngokwe-IFU ngokungqongqo.
Ukhetho lwesi-2.
IMacro & Micro-Test General DNA/RNA Kit (HWTS-3017) kunye neMacro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B).Ukukhutshwa kufuneka kuqhutywe ngokwe-IFU, kwaye umthamo we-elution ocetyiswayo yi-80μL.
Ukhetho lwesi-3.
I-Nucleic Acid Extraction okanye i-Purification Reagent (YDP302) yi-Tiangen Biotech (Beijing) Co., Ltd. Ukukhutshwa kufuneka kuqhutywe ngokuhambelana ngqongqo ne-IFU, kwaye umthamo we-lution okhuthazwayo ngu-80μL.
Iisampulu ze-DNA ezikhutshiweyo kufuneka zivavanywe ngokukhawuleza okanye zigcinwe ngaphantsi kwe-18 ° C ngaphandle kweenyanga ezi-7.Inani lokukhenkceza okuphindaphindiweyo kunye nokunyibilika akufanele kudlule imijikelo emi-4.