I-HPV16 kunye ne-HPV18

Inkcazelo emfutshane:

Le kit intenIfakwe kwi-in vitro ukufunyaniswa komgangatho wamaqhekeza e-nucleic acid ye-human papillomavirus (HPV) 16 kunye ne-HPV18 kwiiseli ezikhutshiweyo zomlomo wesibeleko.


Iinkcukacha zeMveliso

Iithegi zeMveliso

Igama lemveliso

HWTS-CC001-I-HPV16 kunye ne-HPV18 Nucleic Acid Detection Kit (Fluorescence PCR)

I-Epidemiology

Umhlaza womlomo wesibeleko lelinye lawona mathumba ayingozi axhaphakileyo kwindlela yokuzala yabasetyhini.Kuye kwaboniswa ukuba usulelo lwe-HPV oluzingisileyo kunye nosulelo oluninzi ngomnye woonobangela abaphambili bomhlaza womlomo wesibeleko.Okwangoku kusekho ukunqongophala konyango olwamkelekileyo jikelele lomhlaza womlomo wesibeleko obangelwa yi-HPV.Ke ngoko, ukufunyaniswa kwangoko kunye nokuthintela usulelo lomlomo wesibeleko olubangelwa yi-HPV zizitshixo zokuthintela umhlaza womlomo wesibeleko.Ukusekwa kweemvavanyo ezilula, ezicacileyo kunye nezikhawulezayo zokuxilonga iintsholongwane zibaluleke kakhulu kuxilongo lwezonyango lomhlaza womlomo wesibeleko.

Umjelo

Umjelo Uhlobo
FAM HPV18
VIC/HEX HPV16
CY5

Ulawulo lwangaphakathi

IiParameters zobuGcisa

Ugcino

≤-18℃

Beka ubomi kwishelufa Iinyanga ezili-12
Uhlobo loMfanekiso iseli yomlomo wesibeleko exfoliated
Ct ≤28
CV ≤10.0%
LoD Iikopi ezingama-500/mL
Ukuchaza ngokuthe ngqo Xa usebenzisa ikiti ukuvavanya iisampulu ezingezizo ezinokuthi zisabele kwiithagethi zayo, zonke iziphumo zibi, kubandakanywa i-Ureaplasma urealyticum, Chlamydia trachomatis, Candida albicans, Neisseria gonorrhoeae, Trichomonas vaginalis, Mildew, Gardnerella kunye nezinye iintlobo zeHPV ezingagqunywanga yi. ikhithi.
Izixhobo Ezisebenzayo SLAN®-96P Iinkqubo zePCR zeXesha langempelaIinkqubo ze-Biosystems ezisetyenzisiweyo 7500 Iinkqubo zePCR zeXesha langempela

QuantStudio®IiNkqubo ze-PCR ze-5 zeXesha langempela

I-LightCycler®Inkqubo ye-PCR ye-480 yexesha langempela

I-LineGene 9600 Plus ye-Real-Time PCR Detection System (FQD-96A, iteknoloji ye-Hangzhou Bioer)

MA-6000 Real-Time Quantitative Thermal Cycler.

Ukuhamba komsebenzi

Ukhetho1.

I-Macro & Micro-Test Release Sample Release Reagent (HWTS-3005-8), kufuneka ikhutshwe ngokwemiyalelo.

Ukhetho2.

IMacro & Micro-Test General DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) kunye neMacro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006B, HWTS-3006C), kufuneka ikhutshwe ngokwemiyalelo.Umthamo wesampulu ekhutshiweyo yi-200μL, kwaye umthamo we-elution ocetyiswayo yi-80µL.

Ukhetho3.

I-QIAamp DNA Mini Kit (51304) eyenziwe yi-QIAGEN okanye i-TIANamp Virus DNA/RNA Kit (YDP315) eyenziwe yi-Tiangen Biotech (Beijing) Co., Ltd., kufuneka ikhutshwe ngokuhambelana nemiyalelo.Umthamo wesampulu ekhutshiweyo yi-200μL, kwaye umthamo we-elution ocetyiswayo yi-80µL.


  • Ngaphambili:
  • Okulandelayo:

  • Bhala umyalezo wakho apha kwaye uwuthumele kuthi