Mycoplasma hominis, Ureaplasma urealyticum kunye ne Gardnerella vaginalis Nucleic Acid

Inkcazelo emfutshane:

Le khithi ifanelekile ukufunyanwa kwekhwalithi ye-Mycoplasma hominis (MH), i-Ureaplasma urealyticum (UU) kunye ne-Gardnerella vaginalis (GV) kwi-swab ye-urethral yamadoda, i-swab yomlomo wesibeleko, kunye neesampuli ze-vaginal swab, kwaye ibonelela ngoncedo lokuxilongwa kunye nokunyangwa kwezigulane ezinezifo ze-genitourinary tract.


Iinkcukacha zeMveliso

Iithegi zeMveliso

Igama lemveliso

I-HWTS-UR044-Mycoplasma hominis, i-Ureaplasma urealyticum kunye ne-Gardnerella vaginalis i-Nucleic Acid Detection Kit (i-Fluorescence PCR)

I-Epidemiology

I-Mycoplasma hominis (MH) luhlobo lwe-mycoplasma ekhoyo kwi-urinary tract kunye nezitho zangasese kwaye inokubangela ukusuleleka kwintsholongwane kunye nokuvutha kwesini. I-Mycoplasma hominis ikhona ngokubanzi kwindalo kwaye inxulunyaniswa neentlobo ezahlukeneyo zosulelo lwe-genitourinary tract ezifana ne-nongonococcal urethritis, i-cervicitis yabasetyhini, i-adnexitis, i-infertility, njl njl. kunye nosulelo lomgudu womchamo. Kumadoda, kunokubangela i-prostatitis, urethritis, i-pyelonephritis, njl.; kwabasetyhini, kunokubangela ukukrala kwindlela yokuzala efana ne-vaginitis, i-cervicitis, kunye nesifo se-pelvic inflammatory, kwaye yenye ye-pathogens ebangela ukungazali kunye nokuphuphuma kwesisu. Oyena nobangela uqhelekileyo we-vaginitis kwabasetyhini yi-bacterial vaginosis, kwaye ibhaktiriya ebalulekileyo ye-pathogenic ye-bacterial vaginosis yi-Gardnerella vaginalis. I-Gardnerella vaginalis (GV) yintsholongwane engenelelayo engabangeli izifo xa ikhoyo ngemilinganiselo emincinci. Nangona kunjalo, xa iibhaktheriya eziphambili ze-vaginal Lactobacilli zincitshisiwe okanye ziphelisiwe, ezibangela ukungalingani kwindawo yangasese, i-Gardnerella vaginalis iphindaphindeka ngamanani amakhulu, ekhokelela kwi-bacterial vaginosis. Kwangaxeshanye, ezinye iipathogens (ezifana neCandida, Neisseria gonorrhoeae, Mycoplasma hominis, njl.njl.) ziyakwazi ukuhlasela umzimba womntu, zibangele i-vaginitis edibeneyo kunye ne-cervicitis. Ukuba i-vaginitis kunye ne-cervicitis ayifunyaniswanga kwaye inyangwe ngexesha elifanelekileyo, kunokubakho ukonyuka kosulelo ziintsholongwane ecaleni kwendlela yokuzala, ekhokelela ngokulula kusulelo lwendlela yokuzala efana ne-endometritis, i-salpingitis, i-tubo-ovarian abscess (TOA), kunye ne-pelvic peritonitis, enokuthi ikhokelele ekukhulelweni okunzulu kunye nokukhulelwa kwe-ectopic. iziphumo.

Iiparamitha zobuGcisa

Ugcino

≤-18℃

Beka ubomi kwishelufa Iinyanga ezili-12
Uhlobo loMfanekiso i-wab yomchamo oyindoda, i-swab yomlomo wesibeleko yabasetyhini, i-swab yelungu lobufazi
Ct ≤38
CV <5.0%
LoD  UU, GV 400Copies/mL; MH 1000Iikopi/mL
Izixhobo Ezisebenzayo Isebenza ukuchwetheza i-reagent yokubona:

Iinkqubo ze-Biosystems ezisetyenzisiweyo 7500 Iinkqubo zePCR zeXesha langempela,

QuantStudio®IiNkqubo ze-PCR ze-5 zeXesha langempela, 

SLAN-96P Iinkqubo zePCR zeXesha lokwenyani (Hongshi Medical Technology Co., Ltd.),

I-LineGene 9600 Plus Iinkqubo zokuFumana ze-PCR ngexesha langempela (i-FQD-96A, iteknoloji ye-Hangzhou Bioer),

I-MA-6000 yeXesha lokwenyani iBhayisekile yoMyinge weThermal (iSuzhou Molarray Co., Ltd.),

Inkqubo yePCR yeBioRad CFX96 yeXesha lokwenyani,

BioRad CFX Opus 96 Real-Time PCR System.

Isebenza kuhlobo lwe-II yokufumanisa i-reagent:

EudemonTMI-AIO800 (HWTS-EQ007) nguJiangsu Macro kunye neMicro-Test Med-Tech Co., Ltd.

Ukuhamba komsebenzi

IMacro & Micro-Test Viral DNA/RNA Kit (HWTS-3017) (enokuthi isetyenziswe kunye neMacro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)), kunye neMacro & Micro-Test Viral DNA/RNA Kit (HWTS-17u-30)TM I-AIO800 (HWTS-EQ007)) yi-Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

Umthamo wesampulu ekhutshiweyo yi-200μL kwaye umthamo we-elution ocetyiswayo yi-150μL.


  • Ngaphambili:
  • Okulandelayo:

  • Bhala umyalezo wakho apha kwaye uwuthumele kuthi