Asixhenxe Pathogen Urogenital
Igama lemveliso
HWTS-UR017A Seven Urogenital Pathogen Nucleic Acid Detection Kit(Melting Curve)
I-Epidemiology
Izifo ezosulela ngokwabelana ngesondo (STDs) zisesinye sezoyikiso ezibalulekileyo kukhuseleko lwempilo yoluntu lwehlabathi, ezinokukhokelela ekungachumiyo, ukuzalwa kwangaphambi kwexesha, amathumba kunye neengxaki ezinzima ezahlukeneyo.Iintsholongwane eziqhelekileyo ziquka i-chlamydia trachomatis, neisseria gonorrhoeae, mycoplasma genitalium, mycoplasma hominis, herpes simplex virus type 2, ureaplasma parvum, kunye ne-ureaplasma urealyticum.
Umjelo
FAM | I-CT kunye ne-NG |
HEX | MG, MH kunye ne-HSV2 |
ROX | Ulawulo lwangaphakathi |
IiParameters zobuGcisa
Ugcino | ≤-18℃ |
Beka ubomi kwishelufa | Iinyanga ezili-12 |
Uhlobo loMfanekiso | ukukhutshwa kwe-urethra Iimfihlo zomlomo wesibeleko |
Tt | ≤28 |
CV | ≤5.0% |
LoD | CT:500Iikopi/mL NG:400Iikopi/mL MG:1000Iikopi/mL MH:1000Iikopi/mL HSV2:400Iikopi/mL UKUPHEZULU:500Iikopi/mL UU:500Iikopi/mL |
Ukuchaza ngokuthe ngqo | Vavanya iintsholongwane ezosulelekileyo ngaphandle koluhlu lokufumanisa ikiti yovavanyo, ezifana ne-treponema pallidum, i-candida albicans, i-trichomonas vaginalis, i-staphylococcus epidermidis, i-escherichia coli, i-gardnerella vaginalis, i-adenovirus, i-cytomegalovirus, i-beta yeStreptococcus, i-HIV, i-HIV, i-large.Kwaye akukho cross-reactivity. Ikhono lokuchasana nokuphazamiseka: 0.2 mg / mL bilirubin, i-mucus yomlomo wesibeleko, i-106iiseli / mL iiseli zegazi ezimhlophe, i-60 mg / mL mucin, igazi elipheleleyo, isidoda, izidakamizwa ezisetyenziswa ngokuqhelekileyo ze-antifungal (200 mg / mL levofloxacin, 300 mg / mL erythromycin, 500 mg / mL penicillin, 300mg / mL azithromycin, 10% Jieeryin lotion , 5% i-lotion ye-Fuyanjie) musa ukuphazamisa ikiti. |
Izixhobo Ezisebenzayo | SLAN-96P Iinkqubo zePCR zeXesha langempela Inkqubo yePCR yeLightCycler®480 yeXesha langempela |
Ukuhamba komsebenzi
IMacro & Micro-Test General DNA/RNA Kit (HWTS-3019-50, HWTS-3019-32, HWTS-3019-48, HWTS-3019-96) kunye neMacro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B).
A) Indlela ye-Manual: Thatha i-1.5mL DNase / i-RNase-free centrifuge tube kwaye ungeze i-200μL yesampuli ukuba ihlolwe.Amanyathelo alandelayo kufuneka atsalwe ngokungqinelana ne-IFU.Umthamo we-elution ocetyiswayo yi-80μL.
B) Indlela ezenzekelayo: Thatha ikiti yokukhupha i-pre-packageged, yongeza i-200 μL yesampuli ukuba ivavanywe kwindawo ehambelanayo yomthombo, kwaye amanyathelo alandelayo kufuneka akhutshwe ngokuhambelana ne-IFU.