I-Ureaplasma Parvum Nucleic Acid

Inkcazo emfutshane:

Le khithi ifanelekile ekuchongeni i-Ureaplasma Parvum (UP) kwiisampuli zomchamo wamadoda kunye nokukhutshwa kwemveliso yokuzala yabasetyhini, kwaye inceda ekuxilongweni nasekunyangweni kwezigulane ezine-Ureaplasma parvum infection.


Iinkcukacha zeMveliso

Iithegi zeMveliso

Igama lemveliso

Ikhithi yokuFumanisa i-HWTS-UR046-Ureaplasma Parvum Nucleic Acid (iFluorescence PCR)

I-Epidemiology

Iintlobo ze-Ureaplasma ezinxulunyaniswa ne-pathogenesis yabantu zahlulwe zaba zii-biogroups ezi-2 kunye nee-serotypes ezili-14. I-Biogroup Ⅰ yi-Ureaplasma urealyticum, equka ii-serotypes: 2, 4, 5, 7, 8, 9, 10, 11, 12, kunye ne-13. I-Biogroup Ⅱ yi-Ureaplasma parvum, equka ii-serotypes: 1, 3, 6, 14. I-Ureaplasma sisidalwa esiqhelekileyo okanye i-commensal kwindlela yokuzala yabasetyhini kwaye yenye yezona ntsholongwane zibalulekileyo ezibangela izifo ezosulelayo kwinkqubo ye-genitourinary. Ukongeza ekubangeleni usulelo lwe-genitourinary tract, abafazi abanosulelo lwe-Ureaplasma nabo banokuthi badlulisele i-pathogen kumaqabane abo esondo. Usulelo lwe-Ureaplasma lukwayenye yezona zinto zibalulekileyo zokungazali. Ukuba abafazi abakhulelweyo bosulelwe yi-Ureaplasma, oku kunokubangela ukuqhekeka kwe-membranes ngaphambi kwexesha, ukuzalwa ngaphambi kwexesha, isifo sokuphefumla kweentsana ezisandula ukuzalwa, usulelo emva kokubeleka kunye neminye imiphumo emibi yokukhulelwa, efuna ingqalelo enkulu.

Iiparameters zobugcisa

Indawo yokugcina izinto

-18℃

Beka ubomi kwishelufa Iinyanga ezili-12
Uhlobo lweSibonelelo indlela yokuchama yamadoda, indlela yokuzala yabasetyhini
Ct ≤38
CV <5.0%
I-LoD Iikopi ezingama-400/mL
Izixhobo Ezisebenzayo Isebenza kwi-type I detection reagent:

Iinkqubo ze-PCR ze-Applied Biosystems 7500 Real-Time,

I-QuantStudio®Iinkqubo ze-PCR ezi-5 zeXesha langempela,

Iinkqubo ze-PCR ze-SLAN-96P zeXesha langempela (iHongshi Medical Technology Co., Ltd.),

Iinkqubo zokuFumanisa i-LineGene 9600 Plus Real-Time PCR (FQD-96A, iteknoloji ye-Hangzhou Bioer),

I-MA-6000 Real-Time Quantitative Thermal Cycler (iSuzhou Molarray Co., Ltd.),

Inkqubo ye-PCR ye-BioRad CFX96 yeXesha langempela,

Inkqubo ye-PCR ye-BioRad CFX Opus 96 yeXesha langempela.

Isebenza kwi-reagent yokuchonga uhlobo lwesibini:

U-EudemonTMI-AIO800 (HWTS-EQ007) yiJiangsu Macro kunye neMicro-Test Med-Tech Co., Ltd.

Ukuhamba komsebenzi

I-Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017) (engasetyenziswa kunye ne-Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)), kunye ne-Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-8) (engasetyenziswa kunye ne-EudemonTM I-AIO800 (HWTS-EQ007)) yiJiangsu Macro kunye neMicro-Test Med-Tech Co., Ltd.

Umthamo wesampulu ekhutshiweyo yi-200μL kwaye umthamo we-elution ocetyiswayo yi-150μL.


  • Ngaphambili:
  • Okulandelayo:

  • Bhala umyalezo wakho apha uze uwuthumele kuthi