Ureaplasma Parvum Nucleic Acid

Inkcazelo emfutshane:

Le khithi ilungele ukufunyaniswa okusemgangathweni kwe-Ureaplasma Parvum (UP) kwindlela yomchamo yamadoda kunye neesampulu zokuphuma kwendlela yokuzala yabasetyhini, kwaye ibonelela ngoncedo kuxilongo kunye nonyango lwezigulane ezinosulelo lwe-Ureaplasma parvum.


Iinkcukacha zeMveliso

Iithegi zeMveliso

Igama lemveliso

I-HWTS-UR046-Ureaplasma Parvum Nucleic Acid Detection Kit (Fluorescence PCR)

I-Epidemiology

Iintlobo ze-Ureaplasma okwangoku ezinxulumene ne-pathogenesis yabantu zihlulwe zibe yi-2 biogroups kunye ne-14 serotypes. I-Biogroup Ⅰ yi-Ureaplasma urealyticum, equka i-serotypes: 2, 4, 5, 7, 8, 9, 10, 11, 12, kunye ne-13. I-Biogroup Ⅱ yi-Ureaplasma parvum, ebandakanya i-serotypes: 1, 3, 6, 14 i-asal recommen i-product ye-Urea kunye ne-Urea 14. enye yeentsholongwane ezibalulekileyo ezibangela izifo ezithathelwanayo kwinkqubo ye-genitourinary. Ukongeza ekubangeleni usulelo lwe-genitourinary tract, abasetyhini abanosulelo lwe-Ureaplasma nabo banokusasaza i-pathogen kumaqabane abo ngesondo. Usulelo lwe-Ureaplasma lukwangomnye woonobangela ababalulekileyo bobudlolo. Ukuba abafazi abakhulelweyo bosulelwe yi-Ureaplasma, kunokukhokelela ekuqhekekeni kwangaphambi kwexesha kweembrane, ukunikezelwa kwangaphambi kwexesha, i-neonatal breathe distress syndrome, usulelo lwasemva kokubeleka kunye nezinye iziphumo ezibi zokukhulelwa, ezifuna ingqalelo enkulu.

Iiparamitha zobuGcisa

Ugcino

-18℃

Beka ubomi kwishelufa Iinyanga ezili-12
Uhlobo loMfanekiso indoda yomchamo,indlela yokuzala yabasetyhini
Ct ≤38
CV <5.0%
LoD Iikopi ezingama-400/mL
Izixhobo Ezisebenzayo Isebenza ukuchwetheza i-reagent yokubona:

Iinkqubo ze-Biosystems ezisetyenzisiweyo 7500 Iinkqubo zePCR zeXesha langempela,

QuantStudio®Iinkqubo zePCR ezi-5 zeXesha langempela,

SLAN-96P Iinkqubo zePCR zeXesha lokwenyani (Hongshi Medical Technology Co., Ltd.),

I-LineGene 9600 Plus Iinkqubo zokuFumana ze-PCR ngexesha langempela (i-FQD-96A, iteknoloji ye-Hangzhou Bioer),

I-MA-6000 yeXesha lokwenyani iBhayisekile yoMyinge weThermal (iSuzhou Molarray Co., Ltd.),

Inkqubo yePCR yeBioRad CFX96 yeXesha lokwenyani,

BioRad CFX Opus 96 Real-Time PCR System.

Isebenza kuhlobo lwe-II yokufumanisa i-reagent:

EudemonTMI-AIO800 (HWTS-EQ007) nguJiangsu Macro kunye neMicro-Test Med-Tech Co., Ltd.

Ukuhamba komsebenzi

IMacro & Micro-Test Viral DNA/RNA Kit (HWTS-3017) (enokuthi isetyenziswe kunye neMacro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)), kunye neMacro & Micro-Test Viral DNA/RNA Kit (HWTS-17u-30)TM I-AIO800 (HWTS-EQ007)) yi-Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.

Umthamo wesampulu ekhutshiweyo yi-200μL kwaye umthamo we-elution ocetyiswayo yi-150μL.


  • Ngaphambili:
  • Okulandelayo:

  • Bhala umyalezo wakho apha kwaye uwuthumele kuthi