Iindidi ezingama-28 zoMngcipheko ophezulu weNtsholongwane yePapilloma yoMntu (16/18 Ukuchwetheza) i-Nucleic Acid

Inkcazelo emfutshane:

Le khithi ifanelekile kwi-in vitro yokubona umgangatho weentlobo ezingama-28 ze-human papilloma viruss (HPV) (HPV6, 11, 16, 18, 26, 31, 33, 35, 39, 40, 42, 43, 44, 45, 51, 52, 53, 54, 56, 58, 59, 61, 66, 68, 73, 81, 82, 83) i-nucleic acid kumchamo wendoda / wesetyhini kunye neeseli ze-cervical exfoliated.I-HPV 16/18 inokuchwethezwa, iintlobo ezishiyekileyo azikwazi ukuchwethezwa ngokupheleleyo, zibonelela ngeendlela ezincedisayo zokuxilongwa kunye nonyango losulelo lwe-HPV.


Iinkcukacha zeMveliso

Iithegi zeMveliso

Igama lemveliso

I-HWTS-CC006A-28 Iintlobo zeNtsholongwane ePhakamileyo yePapilloma yoMntu (16/18 Ukuchwetheza) Ikhithi yokubona i-Nucleic Acid (Fluorescence PCR)

I-Epidemiology

Umhlaza womlomo wesibeleko lelinye lawona mathumba ayingozi axhaphakileyo kwindlela yokuzala yabasetyhini.Uphononongo lubonise ukuba usulelo oluzingisileyo lwe-HPV kunye nosulelo oluninzi ngomnye woonobangela abaphambili bomhlaza womlomo wesibeleko.Okwangoku, unyango olusebenzayo oluvunyiweyo lusanqongophala lomhlaza womlomo wesibeleko obangelwa yi-HPV, ngoko ke ukufunyanwa kwangoko kunye nothintelo losulelo lomlomo wesibeleko olubangelwa yi-HPV ngundoqo ekuthinteleni umhlaza womlomo wesibeleko.Kubaluleke kakhulu ukuseka uvavanyo olulula, olucacileyo kunye nolukhawulezayo lwe-etiology yokuxilongwa kwekliniki kunye nonyango lomhlaza womlomo wesibeleko.

Umjelo

Umxube wokusabela Umjelo Uhlobo
PCR-Mix1 FAM 18
VIC(HEX) 16
ROX 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, 68
CY5 Ulawulo lwangaphakathi
I-PCR-Mix2 FAM 6, 11, 54, 83
VIC(HEX) 26, 44, 61, 81
ROX 40, 42, 43, 53, 73, 82
CY5 Ulawulo lwangaphakathi

IiParameters zobuGcisa

Ugcino Ulwelo: ≤-18℃
Beka ubomi kwishelufa Iinyanga ezili-12
Uhlobo loMfanekiso I-Swab yeSibeleko, i-Vaginal Swab, Umchamo
Ct ≤28
CV <5.0%
LoD 300Iikopi/mL
Izixhobo Ezisebenzayo Iinkqubo ze-Biosystems ezisetyenzisiweyo 7500 Iinkqubo zePCR zeXesha langempela
Iinkqubo ze-Biosystems eziSetyenzisiweyo 7500 Iinkqubo zePCR ezikhawulezayo
QuantStudio®IiNkqubo ze-PCR ze-5 zeXesha langempela
SLAN-96P Iinkqubo zePCR zeXesha langempela
I-LightCycler®Inkqubo ye-PCR ye-480 yexesha langempela
I-LineGene 9600 Plus Real-Time PCR Detection System
MA-6000 Real-Time Quantitative Thermal Cycler
I-BioRad CFX96 Inkqubo yePCR yexesha lokwenyani
BioRad CFX Opus 96 Real-Time PCR System

Ukuhamba komsebenzi

I-reagent yokutsalwa ecetyiswayo: Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (enokuthi isetyenziswe kunye neMacro & Micro-Test I-Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) yi-Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Yongeza i-200μL ye-saline eqhelekileyo ukumisa kwakhona i-pellet kwinqanaba le-2.1, kwaye ke ukutsalwa kufuneka kuqhutywe ngokuhambelana kwimiyalelo yokusetyenziswa kwesi sixhobo sotsalo.Umthamo we-elution ocetyiswayo yi-80μL.
I-reagent yokutsalwa ecetyiswayo: QIAamp DNA Mini Kit (51304) okanye iMacro & Micro-Test Viral DNA/RNA Column (HWTS-3020-50).Yongeza i-200μL ye-saline eqhelekileyo ukumisa kwakhona i-pellet kwinqanaba le-2.1, kwaye emva koko ukukhutshwa kufuneka kuqhutywe ngokwemiyalelo yokusetyenziswa kwesi sixhobo sokukhupha.Umthamo wesampulu okhutshiweyo weisampulu zonke ziyi-200μL, kwaye umthamo we-elution ocetyiswayo yi-100μL.


  • Ngaphambili:
  • Okulandelayo:

  • Bhala umyalezo wakho apha kwaye uwuthumele kuthi