Iintlobo ezingama-28 ze-Human Papilloma Virus ezinobungozi obuphezulu (16/18 Typing) Nucleic Acid

Inkcazo emfutshane:

Le khithi ifanelekile ekufumaneni iintlobo ezingama-28 zeentsholongwane ze-human papilloma (HPV) (HPV6, 11, 16, 18, 26, 31, 33, 35, 39, 40, 42, 43, 44, 45, 51, 52, 53, 54, 56, 58, 59, 61, 66, 68, 73, 81, 82, 83) ze-nucleic acid kumchamo wamadoda/wabasetyhini kunye neeseli zomlomo wesibeleko zabasetyhini. I-HPV 16/18 inokuchwethezwa, ezinye iintlobo azinakuchwethezwa ngokupheleleyo, zibonelela ngendlela encedisayo yokuxilonga kunye nonyango losulelo lwe-HPV.


Iinkcukacha zeMveliso

Iithegi zeMveliso

Igama lemveliso

Iintlobo ze-HWTS-CC006A-28 ze-Human Papilloma Virus enobungozi obuphezulu (16/18 Typing) I-Nucleic Acid Detection Kit (i-Fluorescence PCR)

I-Epidemiology

Umhlaza womlomo wesibeleko yenye yezona zifo zixhaphakileyo kwindlela yokuzala yabasetyhini. Izifundo zibonise ukuba usulelo oluqhubekayo lwe-HPV kunye nosulelo oluninzi zezinye zezona zizathu ziphambili zomhlaza womlomo wesibeleko. Okwangoku, unyango olusebenzayo oluqatshelweyo alusekho kumhlaza womlomo wesibeleko obangelwa yi-HPV, ngoko ke ukufunyanwa kwangoko kunye nokuthintela usulelo lomlomo wesibeleko olubangelwa yi-HPV yeyona nto iphambili ekuthinteleni umhlaza womlomo wesibeleko. Kubaluleke kakhulu ukumisela uvavanyo olulula, olucacileyo nolukhawulezayo lokuxilonga i-etiology yokuxilongwa kweklinikhi kunye nonyango lomhlaza womlomo wesibeleko.

Itshaneli

Umxube weReaction Itshaneli Uhlobo
I-PCR-Mix1 I-FAM 18
I-VIC(HEX) 16
I-ROX 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, 68
CY5 Ulawulo lwangaphakathi
I-PCR-Mix2 I-FAM 6, 11, 54, 83
I-VIC(HEX) 26, 44, 61, 81
I-ROX 40, 42, 43, 53, 73, 82
CY5 Ulawulo lwangaphakathi

Iiparameters zobugcisa

Indawo yokugcina izinto Ulwelo: ≤-18℃
Beka ubomi kwishelufa Iinyanga ezili-12
Uhlobo lweSibonelelo I-Swab yoMlomo, I-Swab yoBufazi, Umchamo
Ct ≤28
CV <5.0%
I-LoD Iikopi ezingama-300/mL
Izixhobo Ezisebenzayo Iinkqubo ze-PCR ze-Applied Biosystems 7500 Real-Time
Iinkqubo ze-PCR eziSebenzisiweyo ze-7500 ezikhawulezayo zeXesha langempela
I-QuantStudio®Iinkqubo ezi-5 ze-PCR zeXesha langempela
Iinkqubo ze-PCR ze-SLAN-96P zeXesha langempela
I-LightCycler®Inkqubo ye-PCR yeXesha langempela ye-480
Inkqubo yokuHlola i-PCR yeLineGene 9600 Plus ngexesha langempela
I-MA-6000 Real-Time Quantitative Thermal Cycler
Inkqubo ye-PCR ye-BioRad CFX96 yeXesha langempela
Inkqubo ye-PCR ye-BioRad CFX Opus 96 yeXesha langempela

Ukuhamba komsebenzi

I-reagent yokukhupha ecetyiswayo: I-Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (engasetyenziswa kunye ne-Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) yiJiangsu Macro & Micro-Test Med-Tech Co., Ltd. Yongeza i-200μL ye-saline eqhelekileyo ukuze uphinde umise i-pellet kwinyathelo lesi-2.1, kwaye emva koko ukukhupha kufuneka kwenziwe ngokwemiyalelo yokusebenzisa le reagent yokukhupha. Umthamo wokucoca ocetyiswayo yi-80μL.
I-reagent yokukhupha ecetyiswayo: I-QIAamp DNA Mini Kit (51304) okanye i-Macro & Micro-Test Viral DNA/RNA Column (HWTS-3020-50). Yongeza i-200μL ye-saline eqhelekileyo ukuze uphinde umise i-pellet kwinyathelo lesi-2.1, uze emva koko ukukhupha kufuneka kwenziwe ngokwemiyalelo yokusebenzisa le reagent yokukhupha. Umthamo wesampulu ekhutshiweyo weesampuli zonke ziyi-200μL, kwaye umthamo wokucoca ocetyiswayo yi-100μL.


  • Ngaphambili:
  • Okulandelayo:

  • Bhala umyalezo wakho apha uze uwuthumele kuthi