Chlamydia Trachomatis, Neisseria Gonorrhoeae kunye neTrichomonas vaginalis

Inkcazelo emfutshane:

Ikhithi yenzelwe ukufumanisa ubulunga be-in vitro ye-Chlamydia trachomatis (CT), i-Neisseria gonorrhoeae (NG)kwayeI-Trichomonal vaginitis (i-TV) kwi-swab ye-urethral yamadoda, i-swab yomlomo wesibeleko yabasetyhini, kunye neesampuli ze-vaginal swab zabasetyhini, kunye nokubonelela ngoncedo ekuxilongweni kunye nonyango lwezigulane ezinosulelo lwe-genitourinary tract.


Iinkcukacha zeMveliso

Iithegi zeMveliso

Igama lemveliso

HWTS-UR041 Chlamydia Trachomatis, Neisseria Gonorrhoeae kunye neTrichomonas vaginalis iNucleic Acid Detection Kit (Fluorescence PCR)

I-Epidemiology

I-Chlamydia trachomatis (CT) luhlobo lwe-microorganism ye-prokaryotic ene-parasitic ngokungqongqo kwiiseli ze-eukaryotic.I-Chlamydia trachomatis yahlulwe ibe yi-AK serotypes ngokwendlela ye-serotype.Izifo ze-Urogenital zibangelwa kakhulu yi-trachoma biological variant DK serotypes, kwaye amadoda abonakaliswe kakhulu njenge-urethritis, enokuthi ikhululeke ngaphandle konyango, kodwa ininzi yabo ibe yinto engapheliyo, ikhula ngokukhawuleza, kwaye inokudibaniswa ne-epididymitis, i-proctitis, njl.

Umjelo

FAM I-Chlamydia trachomatis
ROX Neisseria gonorrhoeae
CY5 I-Trichomonal vaginitis
VIC/HEX Ulawulo lwangaphakathi

IiParameters zobuGcisa

Ugcino

-18℃

Beka ubomi kwishelufa Iinyanga ezili-12
Uhlobo loMfanekiso Iswabhu yomlomo wesibeleko yabasetyhini,Iswabhu yelungu lobufazi,I-swab ye-urethral yamadoda
Ct ≤38
CV <5%
LoD 400Iikopi/mL
Ukuchaza ngokuthe ngqo Akukho-cross-reactivity kunye nezinye iintsholongwane ze-STD zosulelo ngaphandle koluhlu lokukhangela ikiti yokuvavanya, njenge-Treponema pallidum, i-Mycoplasma hominis, i-Mycoplasma genitalium, i-Herpes simplex virus type 1, i-Herpes simplex virus type 2, i-Candida albicans, njl.
Izixhobo Ezisebenzayo Isetyenziselwe i-Biosystems ye-7500 ye-Real-Time PCR System

Iinkqubo ze-Biosystems eziSetyenzisiweyo 7500 Iinkqubo zePCR ezikhawulezayo

QuantStudio®IiNkqubo ze-PCR ze-5 zeXesha langempela

SLAN-96P Iinkqubo zePCR zeXesha langempela

I-LightCycler®Inkqubo ye-PCR ye-480 yexesha langempela

I-LineGene 9600 Plus Real-Time PCR Detection System

MA-6000 Real-Time Quantitative Thermal Cycler

I-BioRad CFX96 Inkqubo yePCR yexesha lokwenyani

BioRad CFX Opus 96 Real-Time PCR System

Ukuhamba komsebenzi

Ukhetho loku-1.

I-reagent yokutsalwa ecetyiswayo: I-Pipette 1mL yesampuli ukuba ivavanywe kwi-1.5mL ye-DNase / i-RNase-free centrifuge tube, i-centrifuge kwi-12000rpm imizuzu ye-3, ilahle i-supernatant kwaye ugcine i-precipitate.Yongeza i-200µL ye-saline eqhelekileyo kwimvula ukuze umise kwakhona.IMacro & Micro-Test General DNA/RNA Kit (HWTS-3019-50, HWTS-3019-32, HWTS-3019-48, HWTS-3019-96) (enokuthi isetyenziswe kunye neMacro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) nguJiangsu Macro & Micro-Test Med-Tech Co., Ltd. Ukukhutshwa kufuneka kwenziwe ngokomyalelo wokusetyenziswa.Umthamo wesampulu ekhutshiweyo yi-200µL, kwaye umthamo we-elution ocetyiswayo yi-80µL.

Ukhetho lwesi-2.

Isixhobo sokutsalwa esicetyiswayo: Ukutsalwa kwe-Nucleic Acid okanye iKit yokucoca (YDP302).Ukukhutshwa kufuneka kwenziwe ngokungqongqo ngokomyalelo wokusetyenziswa.Umthamo we-elution ocetyiswayo yi-80µL.


  • Ngaphambili:
  • Okulandelayo:

  • Bhala umyalezo wakho apha kwaye uwuthumele kuthi