I-Mycoplasma Genitalium (Mg)

Inkcazelo emfutshane:

Le khithi isetyenziselwa ukukhangela umgangatho we-in vitro we-Mycoplasma genitalium (Mg) nucleic acid kwi-urinary tract yamadoda kunye ne-secretions ye-genitalium yabasetyhini.


Iinkcukacha zeMveliso

Iithegi zeMveliso

Igama lemveliso

I-HWTS-UR014A I-Mycoplasma Genitalium (Mg) I-Nucleic Acid Detection Kit (i-Fluorescence PCR)

I-Epidemiology

Izifo ezosulela ngokwabelana ngesondo (STD) zihlala zisisongelo esikhulu kukhuseleko lwezempilo lukawonke-wonke lwehlabathi, olunokukhokelela ekungazali, ukuzalwa kwangaphambi kwexesha, i-tumorigenesis, kunye neengxaki ezinzima ezahlukeneyo [1-4].Kukho iintlobo ezininzi ze-STD pathogens, kuquka ibhaktheriya, iintsholongwane, i-chlamydia, i-mycoplasma, kunye ne-spirochetes.Iindidi eziqhelekileyo ziquka i-Neisseria gonorrhoeae, i-Chlamydia trachomatis, i-Ureaplasma urealyticum, i-Herpes simplex virus type 1, i-Herpes simplex virus type 2, i-Mycoplasma hominis, i-Mycoplasma genitalium kunye njl.

Umjelo

FAM Mg
ROX

Ulawulo lwangaphakathi

IiParameters zobuGcisa

Ugcino

-18℃

Beka ubomi kwishelufa Iinyanga ezili-12
Uhlobo loMfanekiso uukukhutshwa kwe-rethral,iimfihlo zomlomo wesibeleko
Tt ≤38
CV ≤5.0%
LoD Iikopi ezingama-500/μL
Ukuchaza ngokuthe ngqo Akukho-cross-reactivity kunye nezinye izifo ezithathelwana ngesondo, ezifana neChlamydia trachomatis, Ureaplasma urealyticum, Neisseria gonorrhoeae, Mycoplasma hominis, Herpes simplex virus type 1, kunye neHerpes simplex virus type 2.
Izixhobo Ezisebenzayo Iinkqubo ze-Biosystems ezisetyenzisiweyo 7500 Iinkqubo zePCR zeXesha langempelaQuantStudio®IiNkqubo ze-PCR ze-5 zeXesha langempela

SLAN-96P Iinkqubo zePCR zeXesha langempela

I-LightCycler®Inkqubo ye-PCR ye-480 yexesha langempela

I-LineGene 9600 Plus Real-Time PCR Detection System

MA-6000 Real-Time Quantitative Thermal Cycler

I-BioRad CFX96 Inkqubo yePCR yexesha lokwenyani

BioRad CFX Opus 96 Real-Time PCR System

Ukuhamba komsebenzi

Ukhetho loku-1.

I-Macro & Micro-Test Release Release yeSampuli (HWTS-3005-8), kufuneka ikhutshwengokungqongqongokwemiyalelo.

Ukhetho lwesi-2.

Macro & Micro-Test General DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) kunye Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006B, HWTS -3006C), kufuneka ikhutshwe ngokungqongqo ngokwemiyalelo.Umthamo we-elution ocetyiswayo yi-80µL.

Ukhetho3.

I-Nucleic Acid Extraction okanye iKhiti yokuCoca(YDP302)eyenziwe nguTiangen Biotech (Beijing) Co., Ltd., kufuneka ikhutshwe ngokuhambelana nemiyalelo.Umthamo we-elution ocetyiswayo yi-80µL.


  • Ngaphambili:
  • Okulandelayo:

  • Bhala umyalezo wakho apha kwaye uwuthumele kuthi