SARS-CoV-2/influenza A /influenza B

Inkcazelo emfutshane:

Le khithi ifanelekile kwi-in vitro yokuchongwa komgangatho we-SARS-CoV-2, umkhuhlane A kunye ne-influenza B nucleic acid ye-nasopharyngeal swab kunye ne-oropharyngeal swab iisampulu ngabantu ekurhaneleka ukuba usulelo lwe-SARS-CoV-2, umkhuhlane A kunye nomkhuhlane B. I-SARS-CoV-2, umkhuhlane A kunye nomkhuhlane B nucleic acid kwi-nasopharyngeal swab kunye ne-oropharyngeal swab iisampulu zenoveli yosulelo lweCoronavirus kwezinye iimeko.


Iinkcukacha zeMveliso

Iithegi zeMveliso

Igama lemveliso

I-HWTS-RT148-SARS-CoV-2/umkhuhlane A /umkhuhlane B i-Nucleic Acid eDityanisiweyo yeKhithi yokubona (i-Fluorescence PCR)

Umjelo

Igama lesitishi I-PCR-Mix 1 PCR-Mix 2
FAM Channel Uhlobo lweORF1ab IVA
VIC/HEX Channel Ulawulo lwangaphakathi Ulawulo lwangaphakathi
Ijelo le-CY5 Njini /
Ijelo le-ROX E gene IVB

Iiparamitha zobuGcisa

Ugcino

-18℃

Beka ubomi kwishelufa Iinyanga ezili-12
Uhlobo loMfanekiso i-nasopharyngeal swabs kunye ne-oropharyngeal swabs
Ekujoliswe kuko I-SARS-CoV-2 ezintathu ekujoliswe kuzo (i-Orf1ab, i-N kunye ne-E gene)/umkhuhlane A /umkhuhlane B
Ct ≤38
CV ≤10.0%
LoD SARS-CoV-2:300 Iikopi/mL

intsholongwane yomkhuhlane A:500 Iikopi/mL

intsholongwane yomkhuhlane B:500 Iikopi/mL

Ukuchaza ngokuthe ngqo a) Iziphumo zovavanyo lomnqamlezo zibonise ukuba ikhithi iyahambelana ne-coronavirus yabantu i-SARSr- CoV, i-MERSr-CoV, i-HcoV-OC43, i-HcoV-229E, i-HcoV-HKU1, i-HCoV-NL63, intsholongwane yokuphefumla ye-syncytial virus A kunye ne-B, i-parainfluenza virus 1, 2 kunye ne-3, irhinovirus, i-rhinovirus, i-ade, i-ade I-5, i-7 kunye ne-55, i-metapneumovirus yabantu, i-enterovirus A, B, C kunye ne-D, i-virus ye-cytoplasmic pulmonary virus, i-virus ye-EB, i-virus yemasisi I-cytomegalovirus yabantu, i-rotavirus, i-norovirus, i-mumps virus, i-varicella zoster virus, i-Mycoplasma pneumoniae, i-Chlamydia pneumoniaetus, i-Staphylophilophilus e-Legionela, i-Haesisfluenza aureus, Streptococcus pneumoniae, Streptococcus pyogenes, Klebsiella pneumoniae, Mycobacterium tuberculosis, Aspergillus fumigatus, Candida albicans, Candida glabrata Kwakungekho mpendulo phakathi kwePneumocystis yersini kunye neCryptococcus neoformans.

b) Ikhono lokuchasana nokuphazamiseka: khetha i-mucin (60mg / mL), i-10% (V / V) igazi lomntu, i-diphenylephrine (2mg / mL), i-hydroxymethylzoline (2mg / mL), i-sodium chloride (equlethe i-preservative) (20mg / mL), i-beclomethasone (20mg / mL), i-dexamesomg / mL), i-dexamethamne (20μg/mL), triamcinolone acetonide (2mg/mL), budesonide (2mg/mL), mometasone (2mg/mL), i-fluticasone (2mg/mL), i-histamine hydrochloride (5mg/mL), α-Interferon (800IU/mL0mg/mL0mg/mL), i-2mg/2mg/mL), i-ritamine/i-1mg oseltamivir (60ng/mL), pramivir (1mg/mL), lopinavir (500mg/mL), ritonavir (60mg/mL), mupirocin (20mg/mL), azithromycin (1mg/mL), ceprotene (40μg/mL) Meropenem (200mg/mfloxan/mL) (0.6mg/mL). Iziphumo zibonise ukuba izinto eziphazamisayo kwiimpawu ezingentla zazingenayo impendulo yokuphazamiseka kwiziphumo zokufumanisa iintsholongwane.

Izixhobo Ezisebenzayo Iinkqubo ze-Biosystems ezisetyenzisiweyo 7500 Iinkqubo zePCR zeXesha langempela

Iinkqubo ze-Biosystems eziSetyenzisiweyo 7500 Iinkqubo zePCR ezikhawulezayo

SLAN ®-96P Iinkqubo zePCR zeXesha langempela

IQuantStudio™ 5 Iinkqubo zePCR zeXesha langempela

I-LightCycler®Inkqubo ye-PCR ye-480 yexesha langempela

I-LineGene 9600 Plus Real-Time PCR Detection System

MA-6000 Real-Time Quantitative Thermal Cycler

I-BioRad CFX96 Inkqubo yePCR yexesha lokwenyani

BioRad CFX Opus 96 Real-Time PCR System

Isisombululo sePCR sisonke

ukuhamba komsebenzi

  • Ngaphambili:
  • Okulandelayo:

  • Bhala umyalezo wakho apha kwaye uwuthumele kuthi