Umkhuhlane A/B

Inkcazelo emfutshane:

Le khithi isetyenziselwa ukufunyaniswa komgangatho we-influenza A/B virus nucleic acid kwiisampulu zabantu oropharyngeal swab in vitro.


Iinkcukacha zeMveliso

Iithegi zeMveliso

Igama lemveliso

HWTS-RT003A Influenza A/B Nucleic Acid Detection Kit (Fluorescence PCR)

I-Epidemiology

Intsholongwane yoMkhuhlane A sisifo esosulelayo esinamandla sokuphefumla, esineentlobo ezininzi ezifana ne-H1N1 kunye ne-H3N2, ezithanda ukuguquka kwaye zaqhambuka kwihlabathi jikelele.Ukutshintsha kwe-Antigenic kubhekiselele ekuguqulweni kwentsholongwane yomkhuhlane A, okukhokelela ekuveleni kohlobo olutsha.Iintsholongwane zoMkhuhlane B zohlulwe zibe yimizila emibini emikhulu, iYamagata kunye neVictoria.Iintsholongwane zoMkhuhlane B zine-antigenic drift kuphela, kwaye ziyaluphepha uphononongo kunye nokukhutshwa kwenkqubo yomzimba yokuzikhusela ngoguquko lwazo.Nangona kunjalo, izinga lokuzivelela kwentsholongwane ye-influenza B liyacotha kunelo lentsholongwane yomkhuhlane A, kwaye intsholongwane yomkhuhlane B inokubangela usulelo lwendlela yokuphefumla kwaye ikhokelele kubhubhane.

Umjelo

FAM IFV A
ROX

Ulawulo lwangaphakathi

VIC/HEX IFV B

IiParameters zobuGcisa

Ugcino

≤-18℃

Beka ubomi kwishelufa Iinyanga ezili-9
Uhlobo loMfanekiso i-oropharyngeal swab
Ct ≤28
CV ≤5.0%
LoD IFV A:500Iikopi/mL,IFV B:500Iikopi/mL
Ukuchaza ngokuthe ngqo 1. Cross-reactivity: akukho reactivity cross phakathi kwale kit kunye adenovirus uhlobo 3, 7, human coronavirus SARSr-CoV, MERSr-CoV, HCoV-OC43, HCoV-229E, HCoV-HKU1, kunye HCoV-NL63, cytomegalovirus, enterovirus, parainfluenza virus, virus yemasisi, human metapneumovirus, mumps virus, breathing syncytial virus type B, rhinovirus, bordetella pertussis, chlamydia pneumoniae, corynebacterium, escherichia coli, haemophilus influenzae, jactobacillus, moraraxella catarrhaliosis, tidis , i-neisseria gonorrhoeae, i-pseudomonas aeruginosa, i-staphylococcus aureus, i-staphylococcus epidermidis, i-streptococcus pneumoniae, i-streptococcus pyogenes, i-streptococcus salivarius kunye ne-DNA ye-genomic yabantu.

2. Uvavanyo lokuphazamiseka: Izinto eziphazamisayo zikhethwa njenge-mucin (60mg / mL), igazi lomntu, i-oxymetazoline (2mg / mL), isulfure (10%), i-beclomethasone (20mg / mL), i-dexamethasone (20mg / mL), i-flunisolide ( 20μg/mL), triamcinolone (2mg/mL), budesonide (1mg/mL), mometasone (2mg/mL), fluticasone (2mg/mL), benzocaine (10%), menthol (10%), zanamivir (20mg/mL ), azithromycin (1mg/L), cephalosporin (40μg/mL), mupirocin (20mg/mL), tobramycin (0.6mg/mL), oseltamivir phosphate (60ng/mL), ribavirin (10mg/L), kwaye iziphumo zibonisa ukuba izinto eziphazamisayo kunye nezigxininiso ezingasentla azikho ukusabela okuphazamisayo ekubhaqweni kwekiti.

Izixhobo Ezisebenzayo Isetyenziselwe i-Biosystems ye-7500 ye-Real-Time PCR System

Iinkqubo ze-Biosystems eziSetyenzisiweyo 7500 Iinkqubo zePCR ezikhawulezayo

QuantStudio®IiNkqubo ze-PCR ze-5 zeXesha langempela

SLAN-96P Iinkqubo zePCR zeXesha lokwenyani(Hongshi Medical Technology Co., Ltd.)

I-LightCycler®Inkqubo ye-PCR ye-480 yexesha langempela

I-LineGene 9600 Plus ye-Real-Time PCR Detection System (FQD-96A, iteknoloji ye-Hangzhou Bioer)

I-MA-6000 yeXesha lokwenyani iBhayisekile yoMyinge weThermal (iSuzhou Molarray Co., Ltd.)

Inkqubo ye-BioRad CFX96 yeXesha langempela lePCR kunye neBioRad CFX Opus 96 Inkqubo yePCR yexesha lokwenyani

Ukuhamba komsebenzi

Ukhetho loku-1.

Ii-reagents zokukhutshwa ezicetyiswayo: Macro & Micro-Test General DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (enokuthi isetyenziswe kunye neMacro & Micro-Test I-Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) nguJiangsu Macro & Micro-Test Med-Tech Co., Ltd. Ukukhutshwa kufuneka kuqhutywe ngokwe-IFU.Umthamo wesampuli yokutsalwa ngu200μL.Umthamo we-lution ocetyiswayo yi-80μL.

Ukhetho lwesi-2.

Ii-reagents zokutsalwa ezicetyiswayo: I-Macro & Micro-Test yeSampuli yokuKhupha iReagent (HWTS-3005-8).Ukukhutshwa kufuneka kuqhutywe ngokwe-IFU.

Ukhetho lwesi-3.

Ii-reagents zokutsalwa ezicetyiswayo: I-Nucleic Acid Extraction okanye i-Purification Kit (YDP315-R).Ukukhutshwa kufuneka kuqhutywe ngokwe-IFU.Umthamo wesampulu yokutsalwa yi-140μL.Umthamo we-elution ocetyiswayo yi-60μL.


  • Ngaphambili:
  • Okulandelayo:

  • Bhala umyalezo wakho apha kwaye uwuthumele kuthi