Ikhithi yokuFumanisa iMycoplasma Hominis Nucleic Acid (iFluorescence PCR)
Igama lemveliso
Ikhithi yokuFumanisa iMycoplasma Hominis Nucleic Acid (iFluorescence PCR)
I-Epidemiology
Izifo ezidluliselwa ngesondo (ii-STD) zisesesinye sezona zisongelo zibalulekileyo kukhuseleko lwempilo yoluntu kwihlabathi liphela, ezinokukhokelela ekungazali, ukuzalwa ngaphambi kwexesha komntwana, ukuveliswa kwe-tumorigenesis kunye neengxaki ezahlukeneyo ezinzulu. I-Mycoplasma hominis ikhona kwindlela ye-genitourinary kwaye inokubangela iimpendulo zokudumba kwindlela ye-genitourinary. Usulelo lwe-MH kwindlela ye-genitourinary lunokubangela izifo ezifana ne-non-gonococcal urethritis, i-epididymitis, njl.njl., kunye nakwabasetyhini, okunokubangela ukudumba kwenkqubo yokuzala esasazeka kumlomo wesibeleko. Kwangaxeshanye, ingxaki eqhelekileyo yosulelo lwe-MH yi-salpingitis, kwaye inani elincinci lezigulana linokuba ne-endometritis kunye nesifo sokuvuvukala kwe-pelvic.
Itshaneli
| I-FAM | Ithagethi ye-MH |
| I-VIC(HEX) | Ulawulo lwangaphakathi |
Iiparameters zobugcisa
| Indawo yokugcina izinto | Ulwelo: ≤-18℃ Ebumnyameni |
| Beka ubomi kwishelufa | Iinyanga ezili-12 |
| Uhlobo lweSibonelelo | ukukhupha umchamo, ukukhupha komlomo wesibeleko |
| Ct | ≤38 |
| CV | <5.0% |
| I-LoD | Iikopi ezili-1000/mL |
| Ukuchaneka | Akukho kudibana kwezifo nezinye izifo ezibangelwa zizifo ezidluliselwa zizifo, ezingaphandle koluhlu lokubhaqwa, kwaye akukho kudibana kwezifo ezibangelwa zizifo ezibangelwa zizifo ezibangelwa zizifo ezidluliselwa zizifo kunye ne-chlamydia trachomatis, ureaplasma urealyticum, neisseria gonorrhoeae, mycoplasma genitalium, herpes simplex virus type 1, herpes simplex virus type 2, njl. |
| Izixhobo Ezisebenzayo | Ingalingana nezixhobo zePCR ezikhanyayo ezithengiswayo. Iinkqubo ze-PCR eziSebenzisiweyo ze-7500 ezikhawulezayo zeXesha langempela Iinkqubo ze-PCR zeQuantStudio®5 zeXesha langempela Iinkqubo ze-PCR ze-SLAN-96P zeXesha langempela Inkqubo ye-PCR yeLightCycler®480 yeXesha langempela Inkqubo yokuHlola i-PCR yeLineGene 9600 Plus ngexesha langempela I-MA-6000 Real-Time Quantitative Thermal Cycler Inkqubo ye-PCR ye-BioRad CFX96 yeXesha langempela Inkqubo ye-PCR ye-BioRad CFX Opus 96 yeXesha langempela |
Ukuhamba komsebenzi
Ii-reagents ziyafuneka kodwa azibonelelwa
I-Macro & Micro-Test Release Reagent (HWTS-3005-8), i-Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) kunye ne-Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B). I-Nucleic Acid Extraction okanye Purification Kit (YDP302) evela kwiTiangen Biotech (Beijing) Co., Ltd.
Izinto ezisetyenziswayo ziyafuneka kodwa azibonelelwa
I-1.5mL yetyhubhu ye-centrifuge engena-RNase/DNase, ii-tips ezingena-RNase/DNase, i-ethanol eyomeleleyo, i-pipette, i-desktop centrifuge, i-desktop shaker mixer.