HWTS-UR001A-Chlamydia Trachomatis Nucleic Acid Detection Kit (Fluorescence PCR)

Ukusetyenziswa okucetywayo

Le khithi isetyenziselwa ukuchongwa okusemgangathweni kweChlamydia trachomatis nucleic acid kumchamo oyindoda, i-swab ye-urethral yamadoda, kunye neesampulu zomlomo wesibeleko zabasetyhini.

I-Epidemiology

I-Chlamydia trachomatis (CT) luhlobo lwe-microorganism ye-prokaryotic ene-parasitic ngokungqongqo kwiiseli ze-eukaryotic.I-Chlamydia trachomatis yahlulwe ibe yi-AK serotypes ngokwendlela ye-serotype.Izifo ze-Urogenital zibangelwa kakhulu yi-trachoma biological variant DK serotypes, kwaye amadoda abonakaliswe kakhulu njenge-urethritis, enokukhululwa ngaphandle konyango, kodwa ininzi yabo ibe yinto engapheliyo, ngamaxesha athile, kwaye inokudibaniswa ne-epididymitis, i-proctitis, njl. kunokubangelwa yi-urethritis, i-cervicitis, njl., kunye neengxaki ezinzulu ze-salpingitis.

I-Epidemiology

FAM: Chlamydia trachomatis (CT)·

I-VIC (HEX): Ulawulo lwangaphakathi

PCR Ukwandiswa kweeMeko zokumisela

Inyathelo

Imijikelo

Ubushushu

Ixesha

Qokelela Iimpawu zeFluorescent okanye Hayi

1

1 umjikelo

50℃

5 imiz

No

2

1 umjikelo

95℃

10mins

No

3

40 imijikelo

95℃

15 imizuzwana

No

4

58℃

31 imizuzwana

Ewe

IiParameters zobuGcisa

Ugcino

 ≤-18℃ ebumnyameni

Beka ubomi kwishelufa

Iinyanga ezili-12

Uhlobo loMfanekiso Iimfihlo zendoda ye-urethral, ​​Iimfihlo zoMfazi zomlomo wesibeleko, Umchamo weNdoda
Ct

≤38

CV <5.0%
LoD 400Iikopi/mL
Ukuchaza ngokuthe ngqo

Akukho-cross-reactivity yokukhangela ezinye izifo ezisulelekileyo ze-STD yile khithi, ezifana ne-Treponema pallidum, i-Neisseria gonorrhoeae, i-Ureaplasma urealyticum, i-Mycoplasma hominis, i-Mycoplasma genitalium, njl., ezingaphandle koluhlu lokufumanisa ikiti.

Izixhobo Ezisebenzayo

Iyakwazi ukuhambelana nezixhobo zePCR zefluorescent kwimarike.

Iinkqubo ze-Biosystems ezisetyenzisiweyo 7500 Iinkqubo zePCR zeXesha langempela

Iinkqubo ze-Biosystems eziSetyenzisiweyo 7500 Iinkqubo zePCR ezikhawulezayo

QuantStudio®IiNkqubo ze-PCR ze-5 zeXesha langempela

SLAN-96P Iinkqubo zePCR zeXesha langempela

I-LightCycler®Inkqubo ye-PCR ye-480 yexesha langempela

I-LineGene 9600 Plus Real-Time PCR Detection System

MA-6000 Real-Time Quantitative Thermal Cycler

I-BioRad CFX96 Inkqubo yePCR yexesha lokwenyani

BioRad CFX Opus 96 Real-Time PCR System