Chlamydia Trachomatis Nucleic Acid

Inkcazelo emfutshane:

Le khithi isetyenziselwa ukufumanisa umgangatho weChlamydia trachomatis nucleic acid kumchamo oyindoda, i-swab ye-urethral yamadoda, kunye neesampulu zomlomo wesibeleko zabasetyhini.


Iinkcukacha zeMveliso

Iithegi zeMveliso

Igama lemveliso

HWTS-UR001A-Chlamydia Trachomatis Nucleic Acid Detection Kit (Fluorescence PCR)

Ukusetyenziswa okucetywayo

Le khithi isetyenziselwa ukufumanisa umgangatho weChlamydia trachomatis nucleic acid kumchamo oyindoda, i-swab ye-urethral yamadoda, kunye neesampulu zomlomo wesibeleko zabasetyhini.

I-Epidemiology

I-Chlamydia trachomatis (CT) luhlobo lwe-microorganism ye-prokaryotic ene-parasitic ngokungqongqo kwiiseli ze-eukaryotic. I-Chlamydia trachomatis yahlulwe ibe yi-AK serotypes ngokwendlela ye-serotype. usulelo Urogenital iphecana ubukhulu becala kubangelwa trachoma biological variant DK serotypes, kwaye amadoda ubukhulu becala wabonakaliswa urethritis, nto leyo enokukhululeka ngaphandle unyango, kodwa uninzi lwazo ibe ezingapheliyo, amaxesha mandundu, kwaye inokudityaniswa epididymitis, proctitis, etc. Abasetyhini kunokubangelwa urethritis enzima, sasvicitis, etc.

I-Epidemiology

FAM: Chlamydia trachomatis (CT)·

I-VIC (HEX): Ulawulo lwangaphakathi

PCR Ukwandiswa kweeMeko zokumisela

Inyathelo

Imijikelo

Ubushushu

Ixesha

Qokelela Iimpawu zeFluorescent okanye Hayi

1

1 umjikelo

50℃

5 imiz

No

2

1 umjikelo

95℃

10mins

No

3

40 imijikelo

95℃

15 imizuzwana

No

4

58℃

31 imizuzwana

Ewe

Iiparamitha zobuGcisa

Ugcino

 ≤-18℃ ebumnyameni

Beka ubomi kwishelufa

Iinyanga ezili-12

Uhlobo loMfanekiso Iimfihlo zendoda ye-urethral, ​​Iimfihlo zoMfazi zomlomo wesibeleko, Umchamo weNdoda
Ct

≤38

CV <5.0%
LoD 400Iikopi/mL
Ukuchaza ngokuthe ngqo

Akukho-cross-reactivity yokufumanisa ezinye iintsholongwane ezisulelekileyo ze-STD yile khithi, ezifana ne-Treponema pallidum, i-Neisseria gonorrhoeae, i-Ureaplasma urealyticum, i-Mycoplasma hominis, i-Mycoplasma genitalium, njl., ezingaphandle koluhlu lokufumanisa ikiti.

Izixhobo Ezisebenzayo

Iyakwazi ukuhambelana nezixhobo zePCR zefluorescent kwimarike.

Iinkqubo ze-Biosystems ezisetyenzisiweyo 7500 Iinkqubo zePCR zeXesha langempela

Iinkqubo ze-Biosystems eziSetyenzisiweyo 7500 Iinkqubo zePCR ezikhawulezayo

QuantStudio®IiNkqubo ze-PCR ze-5 zeXesha langempela

SLAN-96P Iinkqubo zePCR zeXesha langempela

I-LightCycler®Inkqubo ye-PCR ye-480 yexesha langempela

I-LineGene 9600 Plus Real-Time PCR Detection System

MA-6000 Real-Time Quantitative Thermal Cycler

I-BioRad CFX96 Inkqubo yePCR yexesha lokwenyani

BioRad CFX Opus 96 Real-Time PCR System

Ukuhamba komsebenzi

002ea7ccf143e4c9e7ab60a40b9e481


  • Ngaphambili:
  • Okulandelayo:

  • Bhala umyalezo wakho apha kwaye uwuthumele kuthi