Mycoplasma Hominis Nucleic Acid
Igama lemveliso
HWTS-UR004A-Mycoplasma Hominis Nucleic Acid Detection Kit (Fluorescence PCR)
I-Epidemiology
Izifo ezosulela ngokwabelana ngesondo (STDs) zisezezinye zezoyikiso ezibalulekileyo kukhuseleko lwempilo yoluntu jikelele, ezinokukhokelela ekungazali, ukuzalwa komntwana ngaphambi kwexesha, i-tumorigenesis kunye neengxaki ezinzima ezahlukeneyo.I-Mycoplasma hominis ikhona kwi-genitourinary tract kwaye inokubangela iimpendulo ezivuthayo kwi-genitourinary tract.Ukusuleleka kwe-MH ye-genitourinary tract kunokubangela izifo ezifana ne-non-gonococcal urethritis, i-epididymitis, njl., kunye naphakathi kwabasetyhini, oku kunokubangela ukuvuvukala kwenkqubo yokuzala esasazeka ngokujoliswe kumlomo wesibeleko.Ngelo xesha, ingxaki eqhelekileyo yokusuleleka kwe-MH yi-salpingitis, kwaye inani elincinci lezigulane linokuba ne-endometritis kunye nesifo sokuvuvukala kwe-pelvic.
Umjelo
FAM | Ithagethi ye-MH |
VIC(HEX) | Ulawulo lwangaphakathi |
IiParameters zobuGcisa
Ugcino | Ulwelo: ≤-18℃ ebumnyameni |
Beka ubomi kwishelufa | Iinyanga ezili-12 |
Uhlobo loMfanekiso | ukukhutshwa kwe-urethral, ukukhutshwa komlomo wesibeleko |
Ct | ≤38 |
CV | <5.0% |
LoD | 1000Iikopi/mL |
Ukuchaza ngokuthe ngqo | Akukho-cross-reactivity kunye nezinye iintsholongwane ze-STD, ezingaphandle koluhlu lokufumanisa, kwaye akukho-cross-reactivity kunye ne-chlamydia trachomatis, ureaplasma urealyticum, neisseria gonorrhoeae, mycoplasma genitalium, i-herpes simplex virus type 1, i-herpes simplex virus type 2 , njl. |
Izixhobo Ezisebenzayo | Iyakwazi ukuhambelana nezixhobo zePCR zefluorescent kwimarike. Iinkqubo ze-Biosystems eziSetyenzisiweyo 7500 Iinkqubo zePCR ezikhawulezayo I-QuantStudio®5 Iinkqubo zePCR zeXesha langempela SLAN-96P Iinkqubo zePCR zeXesha langempela Inkqubo yePCR yeLightCycler®480 yeXesha langempela I-LineGene 9600 Plus Real-Time PCR Detection System MA-6000 Real-Time Quantitative Thermal Cycler I-BioRad CFX96 Inkqubo yePCR yexesha lokwenyani BioRad CFX Opus 96 Real-Time PCR System |
Ukuhamba komsebenzi
Ukhetho loku-1.
I-reagent yokutsalwa ecetyiswayo: I-Macro & Micro-Test Release Sample Release Reagent (HWTS-3005-8).Ukukhutshwa kufuneka kuqhutywe ngokungqongqo ngokuhambelana nemiyalelo.
Ukhetho lwesi-2.
I-reagent yokutsalwa ecetyiswayo: Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (enokuthi isetyenziswe kunye neMacro & Micro-Test I-Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) nguJiangsu Macro & Micro-Test Med-Tech Co., Ltd. Ukukhutshwa kufuneka kuqhutywe ngokungqongqo ngokwemiyalelo.Umthamo we-lution ocetyiswayo kufuneka ube ngama-80 μL.
Ukhetho lwesi-3.
Isixhobo sokutsalwa esicetyiswayo: Ukutsalwa kwe-Nucleic Acid okanye i-Reagent yokucoca (YDP302) yi-Tiangen Biotech (Beijing) Co., Ltd.. Utsalo kufuneka luqhutywe ngokuhambelana ngqongqo nemiyalelo kunye nomthamo we-lution ocetyiswayo yi-80µL.